logo
Dom ProduktyNieniszczący sprzęt testujący

Multi Range Wet Film Thickness Roller Portable Varnish Adhesive Film Measuring Wheel

Najlepsze produkty
Orzecznictwo
Chiny HUATEC  GROUP  CORPORATION Certyfikaty
Chiny HUATEC  GROUP  CORPORATION Certyfikaty
Opinie klientów
szeroka gama produktów NDT, możemy uzyskać wszystko w grupie huatec. Wolimy kupować od nich. Rudolf Shteinman Rosja

—— Rudolf Shteinman

Podoba mi się serwis, bardzo szybka reakcja, profesjonalna praca. Aret Turcja

—— Aret Kaya

Tester twardości huatec, bardzo dobrej jakości, jesteśmy bardzo zadowoleni z przenośnego testera twardości RHL-50. Kumaren Govender Sotuth Africa

—— Kumaren Govender

Im Online Czat teraz

Multi Range Wet Film Thickness Roller Portable Varnish Adhesive Film Measuring Wheel

Multi Range Wet Film Thickness Roller Portable Varnish Adhesive Film Measuring Wheel
Multi Range Wet Film Thickness Roller Portable Varnish Adhesive Film Measuring Wheel Multi Range Wet Film Thickness Roller Portable Varnish Adhesive Film Measuring Wheel

Duży Obraz :  Multi Range Wet Film Thickness Roller Portable Varnish Adhesive Film Measuring Wheel

Szczegóły Produktu:
Miejsce pochodzenia: Chiny
Nazwa handlowa: HUATEC
Orzecznictwo: CE
Zapłata:
Minimalne zamówienie: 1 szt
Czas dostawy: 7-10 dni roboczych po otrzymaniu płatności
Zasady płatności: T/T, PayPal
Możliwość Supply: 10 zestawów/miesiąc

Multi Range Wet Film Thickness Roller Portable Varnish Adhesive Film Measuring Wheel

Opis
Tworzywo: Wysokiej jakości stal nierdzewna Zakres pomiarowy: 0-50 μm, 0-100 μm, 0-150 μm, 0-200 μm,0~300μm, 0-500 μm,0~1000μm
Dokładność pomiaru: nie przekraczać 30 µm Uasge: sprawdzić grubość mokrej powłoki
Podkreślić:

wet film thickness roller

,

portable varnish measuring wheel

,

adhesive film thickness gauge

Multi Range Wet Film Thickness Roller Portable Varnish Adhesive Film Measuring Wheel


I. Uses and Overview

This instrument is designed and manufactured in accordance with the requirements of the international standard ISO2808-1974 (E) "Paints and varnishes - Determination of Film Thickness". It is mainly used to measure the thickness of the wet film on the painted surface and can roughly estimate the approximate thickness of the dry film. This instrument can be used both in the laboratory and for production control.

II. Technical Guidance

Measurement range 0-50 μ m, 0- 100 μ m, 0- 150 μ m, 0- 200 μ m,0~300μm, 0- 500 μ m,0~1000μm
measurement accuracy not exceed 30 μ m


III. Usage and Operation Methods

1.Apply the coating onto a flat plate (rigid substrate) of appropriate hardness. The test plate area must be large enough so that the distance between the paint film thickness measurement point and either side of the test plate is at least 25mm. Measure the wet film thickness immediately after application.

2. Fix the test plate on a suitable level foundation so that it will not move or jump during the measurement of the paint film. Place the instrument on the wet film of the thickness to be measured, with the small reading at the top and the large gap between the instrument's eccentric wheel and the wet film exactly above the wet film. Then roll it forward by half a turn (180°) and repeat it in the opposite direction by half a turn (180°), then move it. Check the position where the central rim of the instrument first contacts the wet film surface, read the value and calculate its average to become a reading.

3. If the topcoat contains volatile solvents or has a low solid content, it is advisable to apply it to the freshly coated film. Additionally, take at least one separate reading and calculate the average of these individual readings.

Note: Although this instrument is suitable for measuring the wet film thickness coated on a flat test plate, it can also be used on the surface of workpieces that are bent in only one direction on-site or in factories, as long as the substrate does not bend between the two concentric wheels to the point where it affects the instrument's measurement.

IV. Result Evaluation

When the linear center section of each scale is used, that is, about 80% of the total scale range is used, the accuracy is high.

V. Precautions

After applying the coating on a hard flat test board in the laboratory or on the surface of the workpiece to be coated on-site, the thickness of the wet paint film should be measured as soon as possible to reduce the thinning of the paint film caused by solvent evaporation.

After use, the instrument should be wiped clean and placed in a dry area.

When the instrument is not in use for a long time, it should be coated with oil for rust prevention treatment.

Multi Range Wet Film Thickness Roller Portable Varnish Adhesive Film Measuring Wheel 0

Multi Range Wet Film Thickness Roller Portable Varnish Adhesive Film Measuring Wheel 1

Multi Range Wet Film Thickness Roller Portable Varnish Adhesive Film Measuring Wheel 2


Szczegóły kontaktu
HUATEC GROUP CORPORATION

Osoba kontaktowa: Ms. Shifen Yuan

Tel: 8610 82921131,8618610328618

Faks: 86-10-82916893

Wyślij zapytanie bezpośrednio do nas (0 / 3000)